Dehumidifier Calculator

    Size a dehumidifier for a home or basement, work out pints per day and units needed for a water loss, or count air movers. Free, no login.

    Estimates use typical ranges — verify against the current S500 and local pricing.

    Recommended dehumidifier capacity

    17 pints/day

    12 pints/day for the first 500 sq ft, plus 5 pints/day for each additional 500 sq ft (moderately damp).

    Sizing guidance from Energy Star / AHAM — energystar.gov/products/dehumidifiers.

    Dehumidifier pint ratings depend on the test procedure used, so a unit rated today can show a lower pint number than an older unit with similar real capacity. Compare ratings on the same basis.

    Last updated:

    What size dehumidifier do I need?

    For an ordinary damp home or basement, size the unit on the floor area and how damp the space feels, and buy capacity in pints removed per day. The home tab above uses the Energy Star and AHAM approach: a base capacity for the first 500 square feet, plus an increment for every additional 500 square feet, stepped up as the space gets damper.

    "Damp" is a judgement, so the tool describes each level rather than asking for a number. Slightly damp means a musty smell in humid weather. Moderately damp means that smell most of the time. Very damp means visible damp patches on walls or the floor. Wet means seepage or standing water. Every step up moves more water, so every step up needs more capacity.

    Two things trip people up when buying. The first is pint ratings: they changed under the 2019 Department of Energy test procedure, so a unit sold today can carry a lower pint number than an older unit of genuinely similar capacity. Compare like with like. The second is ceiling height — the standard tables assume ordinary eight-foot ceilings, and a tall or open space needs more.

    None of this applies to a building that just flooded. Household sizing is designed to hold a comfortable humidity level in an already dry structure, not to pull thousands of grains out of soaked materials. For that, use the water damage tab.

    How many dehumidifiers do I need for water damage?

    Divide the volume of the drying chamber by the sizing factor for the Class of loss and the machine type, then divide that required capacity by what one unit is rated to deliver and round up. The restoration tab does this and prints the arithmetic underneath the answer.

    Note that the calculation is based on volume, not floor area. A 300 square foot room with a cathedral ceiling holds far more air than the same footprint under an eight-foot ceiling, and the equipment has to process all of it. Enter length, width and height, or enter cubic feet directly if you have already measured it.

    The answer is a starting point for the first day, not a specification for the whole job. It assumes a reasonably sealed chamber, and it knows nothing about how much water is actually in the materials, how much outdoor air is leaking in, or how cold the building is. Set the equipment, take readings the next day, and adjust from what the readings tell you.

    How is dehumidification sizing calculated?

    Refrigerant machines are sized by dividing cubic feet by a factor to get required pints per day; desiccants are sized by airflow, multiplying cubic feet by an air-change rate and dividing by sixty to get required CFM. The two machine types do different physics, so they are specified in different units.

    The refrigerant version is: required pints per day = cubic feet ÷ class factor. A smaller factor means more capacity per cubic foot, which is why the factor tightens as the Class rises. Then units needed = ceiling of (required pints ÷ the unit's AHAM rating).

    The desiccant version is: required CFM = cubic feet × air changes per hour ÷ 60. Desiccants are rated by process airflow rather than pints, because what they do is pass air across a moisture-adsorbing wheel — the amount of water removed depends on the condition of the air being passed, not on a condenser coil.

    Every factor and air-change value used here is a placeholder in this build, marked for verification against the IICRC dehumidification-factors document.

    Why Class changes the number

    Class describes how much water the materials absorbed and how hard it will be to get back out, so it is a direct proxy for the evaporation load the equipment has to keep up with. Category describes contamination and changes what you remove; Class describes wetness and changes how much equipment you set.

    A Class 1 loss is a small wet area in materials that barely absorbed anything, so very little water needs to evaporate. A Class 3 loss came from overhead and saturated walls, ceilings and contents, so an enormous amount of water is waiting to evaporate into the same volume of air. Same room, same cubic feet, completely different demand.

    Class 4 is different again: water held deep inside dense materials such as hardwood, plaster, stone and concrete. The limit there is not air capacity but how slowly the water migrates out of the material, which is why Class 4 work leans on very low humidity, specialty drying systems and time. See Categories and Classes for the full breakdown.

    LGR vs conventional vs desiccant

    Conventional refrigerants are cheapest and fade as air gets cool and dry, LGR machines keep pulling water in drier air, and desiccants keep working in cold air where a coil would freeze. The choice follows the conditions the job will end up in, not the conditions it starts in.

    A conventional refrigerant unit condenses water on a cold coil. That works well in warm, wet air, which is exactly what you have on day one. As the chamber dries out and cools, the coil approaches freezing and the machine spends more time in defrost than in production.

    An LGR unit pre-cools the incoming air before it reaches the coil, so it can keep condensing water in air that a conventional machine can no longer touch. That is why it is the common choice for finishing a job as much as starting one.

    A desiccant adsorbs vapor onto a wheel and drives it off with heat, so there is no coil and no freezing limit. It produces very dry, hot process air, which suits cold buildings, large open structures and Class 4 materials that need extreme vapor pressure differentials. The trade-off is heat, power and generally a hire arrangement rather than something on the truck.

    Is my dehumidifier working? Grain depression

    Take temperature and relative humidity at the intake, take them again at the exhaust, convert both to grains per pound, and subtract — that difference is grain depression and it is the only quick proof a machine is producing. The GPP calculator has a preset that does both conversions and the subtraction.

    A machine with a failed compressor, a blocked filter, a leaking refrigerant circuit or a stuck defrost still hums and still blows warm air out of the exhaust. Nothing about standing in front of it tells you it has stopped removing water. The grain numbers do, in about thirty seconds.

    Do it on the first visit and on every monitoring visit, and write the numbers down. Discovering on day four that one unit has been a fan heater since day one costs you the whole job's schedule. No target depression value is published here.

    To turn a depression reading into pints, read down to the machine's process airflow and across to the grain depression you measured. Every figure below is calculated from airflow, grains and air density, not from a manufacturer's rating.

    Pints of water removed per day by process airflow and grain depression
    CFM10 gr20 gr30 gr40 gr50 gr60 gr
    100142843577185
    15021436485106128
    200285785114142170
    2503571106142177213
    3004385128170213256
    40057114170227284341
    Pints per day = process airflow × grain depression ÷ air density, using an 80°F / 60% RH reference air state at sea level. This is what a machine is actually removing on your job, which is not the same as the rating on its data plate.

    Use it as a sanity check on the equipment you already have running: a unit moving 250 CFM at a 10-grain depression is doing a fraction of the work the same unit does at 40 grains, and both look identical from across the room. Convert your intake and exhaust readings to grains with the GPP calculator first.

    How many air movers do I need?

    Count one air mover per set area of wet floor, add one per set length of wet wall, and never go below a minimum per affected room. The air mover tab applies those three rules together and reports the larger of the calculated total and the room minimum.

    The reason for the wall term is that wet walls are a separate surface with their own boundary layer; floor coverage alone leaves them still. The reason for the room minimum is that a small room with barely any wet floor still needs air moving through it to prevent dead pockets of saturated air in corners and behind doors.

    Placement decides whether the count means anything. Air movers work by directing airflow along a wet surface at a shallow angle, in a consistent direction around the room, so air keeps circulating rather than colliding. Pointing several units at the same wet patch from different directions moves less water than the same units set to sweep the perimeter.

    Every placement figure in this build is a placeholder.

    When to add or pull equipment

    Add equipment when the readings stop improving and the materials are still wet; pull equipment when materials reach the drying goal, not when a certain number of days have passed. Daily monitoring is what turns an initial sizing calculation into a correct one.

    Signals to add dehumidification: chamber grains flat or rising day over day, a drying gap that will not open, machines running with little depression because they are overwhelmed, or a section of the structure nobody has been able to get airflow into.

    Signals to pull: material moisture content at the drying goal set from unaffected reference materials, chamber grains steady and low, and no further daily change in the readings. Pulling air movers first and leaving dehumidification a little longer is a common sequence, because evaporation is finished before the air is fully conditioned.

    Everything you add shows up on the invoice as unit-days, which is why the cost calculator asks for equipment counts and drying days rather than a flat rate.

    Common mistakes

    • Sizing on floor area for a restoration job. The calculation is volumetric. High ceilings need more.
    • Treating the AHAM rating as the output you will get. It is a test-condition figure, not a jobsite promise.
    • Using household sizing on a flooded building. Different problem, different method, badly undersized result.
    • Never checking grain depression. A dead machine looks exactly like a working one.
    • Adding air movers to fix slow drying. If the dehumidification cannot keep up, more evaporation makes the air wetter and drying slower.
    • Leaving the chamber open. Every doorway to unconditioned space is capacity spent on the rest of the building.
    • Setting equipment and coming back in three days. Sizing is an estimate; monitoring is the correction.

    Frequently asked questions

    Work out the volume of the affected space in cubic feet, divide it by the sizing factor for the Class of loss and the type of machine you are using, then divide the required capacity by the rating of one unit and round up. The restoration tab above does that arithmetic and shows the formula it used. Treat the answer as a starting point, not a final count.

    The common approach is one air mover per set number of square feet of wet floor, plus one per set number of linear feet of wet wall, with a minimum per room. Enter your wet floor area, wet wall length and room count in the air mover tab and it applies those rules. Placement matters as much as count: they need to move air along wet surfaces, not into each other.

    For an ordinary damp basement, size it on square footage and how damp the space is, using the Energy Star and AHAM guidance in the home tab above. That guidance is for controlling humidity in an occupied space over time. It is not the right method for a basement that just flooded, which needs restoration sizing instead.

    It will remove some water, but household units are designed to hold a comfortable humidity level in a dry building, not to pull grains down hard in a saturated one. They lose capacity quickly as the air gets cooler and drier, which is precisely the condition a drying chamber creates. Restoration units are rated and built for that duty.

    AHAM ratings are measured at a standard test condition, so they describe capacity in that condition rather than on your job. In cooler or drier air a refrigerant unit removes far less than its rating; in hot saturated air it can remove more. Size with the rating, then verify with grain depression readings on site.

    Yes for restoration sizing, because that calculation is based on the volume of air in cubic feet rather than the floor area. A room with a twelve-foot ceiling holds half again as much air as the same footprint with an eight-foot ceiling, and the equipment has to process all of it.

    Yes. They do different jobs. Air movers break the boundary layer of still, saturated air sitting against wet surfaces so evaporation can continue; the dehumidifier removes the vapor they release into the room. Run one without the other and you either stop evaporating or fill the building with moisture.

    The structure of the calculation follows the standard industry approach, but every factor in this build is a placeholder marked for verification, not a published figure. Check the output against the IICRC dehumidification-factors document and your equipment manufacturer's performance data before you rely on it for a job.

    Try the free 20-question practice test — scenario questions on the topics the WRT exam covers, with an explanation after every answer.

    Want the full-length timed exam? Create a free account — no card required.